Project Description

Proposed Alternative Solution for providing 65 mm diameter standpipe hose connections within the exit stairs (and as required on the floor areas for additional coverage purposes) in lieu of traditional fire hose cabinets (containing 38 mm connections and 30 m of fire hose) for the proposed building to be located at 2760 Dundas Street West in Toronto, Ontario. This correspondence has been prepared with respect to the fire and life safety requirements in Part 3 of the 2012 Ontario Building Code (OBC, O.Reg. 332/12 as amended to O.Reg. 158/24) as well as the Alternative Solution Proposal requirements in Division C, Article 2.1.1.1 of the OBC.