Project Description

Alterative solution to use grade TP 304 SCH 10 and 40 stainless steel (SS) pipe as alternate to type L Cooper for domestic cold water main riser for added safety of higher working pressure rating of SS pipe (listed @ 1000 PSIG) compared to Tupe L Copper (listed @ 504 PSIG). SS pipe proposed to installed using victaulic rigid coupling style 89 and 107N for joint fittings.

Permit Details

Permit TypeAS Alternative Solution
Work TypeAlternative Solution
Structure TypeN/A
Revision00
WardS1228
Builder/OwnerN/A