Project Description
Alternative Solution to the Egress from the third and fourth storeys within the dwelling units with respect to OBC 3.3.4.4.(4). Balconies with 1 h fire resistance rating will be provided on levels three and four. An enclosed exit stair will be provided with a door on both levels. To reduce smoke spread sprinklers will be provided around the opening between level two and three, and the doors around the landing on levels three and four will be provided with self closing devices.The compensatory measures are intended to achieve compliance with the OBC by satisfying the functional andobjective statements associated with OBC 3.3.4.4.(4).o Block 08 - 18 - 229611, Block 09 - 18 -229956, Block 10 - 18 -229969, Block 11 - 232602Block 12 - 18 - 233523, Blcok 13 - 18 - 235863, Block 14 - 18 -235870, Block 15 18 -235877, Block 16 - 18 - 235885, Block 17 - 18 - 235897, Block 18 - 18 - 232663, Block 19 - 18 - 232685, Block 20 - 18 - 232698, Block 21- 18 - 232737.
Permit Details
| Permit Type | AS Alternative Solution |
| Work Type | Alternative Solution |
| Structure Type | N/A |
| Revision | 00 |
| Ward | N0628 |
| Builder/Owner | N/A |